Release v0.3 | October 13, 2026

TS2068 Diagnostic Lab cartridge v0.3 - October 13, 2026

This release adds configurable mixed-load and quiet/busy power-cycle tests:
RAM/March, normal/ECM/hires video, 60 Hz IRQ, banking, stronger AY/envelope/beeper
activity and stack-data comparisons. Main L/P selects combined loads; choose
N one batch or C continuous, then S. Genuine IM1/IM2 returns use separate R
confirmation and fresh prerequisites. The running screen explains the6-second
notice. Soak notices remain readable for6 seconds.

Transient read/POP reports now retain the original observed byte, with checked
D0-D7 and multi-bit masks in all RAM regions. The motivating Sinistar D1-loss
incident is a supplied report, not a physically reproduced result.

The updated PDF/offline manual and POWER_LOAD_TROUBLESHOOTING.md explain why
load transitions matter, how to inspect the5 V rail with an oscilloscope and
how to separate supply hypotheses from RAM/refresh/timing faults.

Images and checksums are emulator validated. Physical supply/current/thermal
validation remains pending. HOME U16 retains reduced coverage without L.
Internal diagnostic-v02 filenames are retained for build/tool compatibility;
the public release archives and manifests identify v0.3.